Configuring Your Controller
86 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
Setting the Size of Volumes Created with
Auto-Carving
You can use auto-carving to divide units larger than 1 TB into multiple
volumes. You control the size of the volumes to be created by setting the carve
size (referred to as carving factor in 3BM). The carve size can be between
1TB (1024 GB) and 32 TB (32768 GB); the default is 2 TB.
When you change this policy, it applies to units you create in the future.
Existing units will not be affected.
To set the carve size in 3DM 2
1 Choose
Management > Controller Settings from the menu bar in
3DM 2.
2 In the Other Controller Settings section at the bottom of the screen, in the
Carve Size field, enter the size you want (between 1024 GB and
32768 GB) to use and click
Submit.
The page refreshes, and a message at the top confirms the change you
have made.
To set the carve size (carving factor) in 3BM
1 On the main 3BM screen,
Tab to Settings and press Enter.
2 On the pop-up menu, select
Controller Policies and press Enter.
3 On the Policy Settings page,
Tab to the Carving Factor field, press Enter
to display the text entry box, enter the size you want (between 1024 GB
and 32768 GB) and press
Enter again to accept it.
4
Tab to OK and press Enter to select it.
The policy is enabled immediately.
Enabling and Setting Up Staggered Spin-up
You can set the number of SAS and SATA drives that will spin up at the same
time and the delay time between drive group spinups. This does not apply to
SAS or SATA drives that are attached to an expander.
Three policy settings let you set the number of drives that will spin up at the
same time and set the delay between drive groups that spin up at one time.
Not all SATA drives support staggered spinup. If you enable staggered spinup
and have drives that do not support it, the setting will be ignored. You can
change these settings in 3BM or using the CLI.
Page view 97
1 2 ... 93 94 95 96 97 98 99 100 101 102 103 ... 341 342

Comments to this Manuals

Vikivzn 04 Jan 2024 | 18:05:44

urenrjrjkvnm

Evazoy 07 Jan 2024 | 02:42:43

Med

Renatimzn 07 Jan 2024 | 10:55:43

urenrjrjkvnm

Davidvmm 10 Jan 2024 | 12:36:21

coin

Davidefb 11 Jan 2024 | 12:24:30

coin

Viktorijsw 11 Jan 2024 | 20:38:33

Cinema