Error and Notification Messages
www.lsi.com/channel/products 257
000C Initialize started
Event Type
Information
Cause
The 3ware RAID controller started an initialization. This is always a
“synching” background initialization and does not erase user data.
Initialization either occurs at unit creation time for larger RAID 5, 6, or 50
units or later during the initial verification of redundant units.
Action
Allow the initialization to complete. This will return the unit to its normal
redundant state.
See Also
For more information, see “About Initialization” on page 152
000E Initialize failed
Event Type
Error
Cause
The 3ware RAID controller was unable to complete the initialization. This
error can be caused by unrecoverable drive errors.
If this unit was a redundant unit, and the initialization failed because of a
problem on a particular disk drive, then the unit will be degraded.
Action
If the unit was degraded, then rebuild the unit. This may necessitate replacing
the drive.
Check physical cable and power connections. You can also run the drive
manufacturers diagnostic and repair utilities on the drive.
See Also
For links to drive manufacturer diagnostic utilities and troubleshooting
advice, search the LSI Knowledge Base for keyword 10894 (use the
Advanced Search) at
https://selfservice.lsi.com/service/main.jsp
Page view 268
1 2 ... 264 265 266 267 268 269 270 271 272 273 274 ... 341 342

Comments to this Manuals

Vikivzn 04 Jan 2024 | 18:05:44

urenrjrjkvnm

Evazoy 07 Jan 2024 | 02:42:43

Med

Renatimzn 07 Jan 2024 | 10:55:43

urenrjrjkvnm

Davidvmm 10 Jan 2024 | 12:36:21

coin

Davidefb 11 Jan 2024 | 12:24:30

coin

Viktorijsw 11 Jan 2024 | 20:38:33

Cinema