Troubleshooting
270 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
0033 Migration started
Event Type
Information
Cause
The 3ware RAID controller has started the migration of a unit.
Migration changes can include:
• Expanding capacity of a unit by adding drives
• Changing RAID levels, for example, from RAID 1 to RAID 5
See Also
“RAID Level Migration (RLM) Overview” on page 123
0034 Migration failed
Event Type
Error
Cause
The migration of a unit has failed.
Migration changes can include:
• Expanding capacity of a unit by adding drives.
• Changing RAID levels, for example, from RAID 1 to RAID 5
Action
Review the list of events on the Alarms page for other entries that may give
you an idea of why the migration failed (for example, a drive error on a
specific port).
You may also wish to get the logs and contact technical support at
http://www.lsi.com/channel/ContactUs. For information on collecting logs,
search the LSI Knowledge Base for keyword 12278 (use the Advanced
Search) at
https://selfservice.lsi.com/service/main.jsp.
See Also
“RAID Level Migration (RLM) Overview” on page 123